- Home
- ยป
- Our Products
- »
- Flow Meter
Flow Meter
Endress + Hauser Gas Flow Meter
Minimum Order Quantity: 1 Number
Brand | ENDRESS + HAUSER |
Line Size | 1/2 inch to 24 inches |
Flow Output | 4 to 20 mA |
Measurement Units | Kg/hr |
Retransmission | Industrial Grade Isolated 4-20 mA & RS485 MODBUS interface to SCADA to DCS |
Operating Pressure Range | 16 bar standard,Higher on demand |
Ultrasonic Level Transmitter
Minimum Order Quantity: 1 Piece
Type | Digital |
Model Name/Number | FMU30 |
Brand | ENDRESS + HAUSER |
Packaging Type | 1 |
Usage/Application | WATER |
Cost effective all-round instrument for level applications in liquids and bulk solids
Quick and simple commissioning via menu-guided onsite operation with four-line plain text display, 7 languages selectable
Envelope curves on the on-site display for simple diagnosis
Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate
Non-contact measurement method minimizes service requirements
Installation possible from thread G 1½ or 1½ NPT upwards
Integrated temperature sensor for automatic correction of the temperature dependent sound velocity
Additional Information:
- Item Code: 1
- Production Capacity: 1
- Delivery Time: READY STOCK
Ph Electrodes Sensor
Product Brochure
Model Name/Number | ANY |
Range | ANY |
Part Number | ANY |
Sensor Type | ANY |
Brand | Endress + Hauser |
Cable Length | ANY |
Type Of Ph Meter | ANY |
Accuracy | ANY |
Brand | ENDRESS HAUSER |
Type | Magnetic Sensor, Photocell |
Portable | Yes |
Condition | New |
Material |
|
Color | Blue, silver |
Products for high-quality pH measurement in all industries
More than 30% of all quality-relevant measurements in processes are pH measurements. That''s why reliable pH sensors transmitters are extremely important for plant optimization and process safety. We offer an extensive portfolio for all conditions, such as stable processes, fast changing media compositions, sticky media, hazardous areas or hygienic applications. Discover our ISFET, enamel or glass pH sensors, transmitters, assemblies and calibration solutions
Additional Information:
- Delivery Time: 2 WEEKS
Electromagnetic Flow Meter
Material | Stainless Steel |
Brand | ENDRESS + HAUSER |
Connection | Flange/Wafer |
Display | LCD, Digital |
Accuracy | +/-0.5% from 5 to 100% Qs |
Communication | RS485 |
Environment Temp. | 50 to 55 degree C |
Frequency | 50 to 60 Hz |
Max. Pressure | 145 psi |
Measuring Range | 0.5 m/sec for Minimum & 5m/sec for Maximum |
Output Current | 4 to 20 mA with galvanic isolation |
Voltage | 24 VDC |
Diameter Nominal | 15 to 400 mm |
Installation | Inline Flange Type |
Repeatability | 0.3% |
Cable Length for Remote | 10 meters |
Make :- ENDRESS + HAUSER
Gas Flow Meter
Line Size | 0.5 to 10 Inch |
Pack Type | Box |
Power Supply | AC 85 to 230V, 50/60Hz or DC 24V or Battery (3 year) |
Operating Temperature | -20 to 120 Deg C |
Material | SS |
Base Rating | IP67, IP65 |
Output Signal | 4 to 20mA DC and Pulse(Standard) |
Connection | Flanged, Threaded |
Accuracy | 1.0 to 0.5% |
Media | Liquids (Clear) /Compressed Air |
Make :- ENDRESS + HAUSER
Vortex Gas Flow Meter
Brand | Vortex |
Operating Pressure | 78kg/cm2 |
Operating Temperature | -40 to 350 Degree C |
Repeatability | +/-0.2%of reading |
Communication | RS-485 |
Measurement | Conductive liquid |
Output | 4-20mA |
Connection | Flanged |
Make :- ENDRESS + HAUSER
Vortex Micro Gas Flow Meter
Output | 4 to 20mA DC and Pulse(Standard) |
Nominal Diameter | 100 mm |
Accuracy | 1 to 3.3% of Actual Flow Rate |
Pack Type | Box |
Operating Pressure | 8 to 428m3/h |
Brand | Vortex |
Power Supply | AC 85 to 230V, 50/60Hz or DC 24V or Battery (3 year) |
Operating Temperature | 5 to 70 deg C |
Temperature | -40 to +350 degree Celsius |
Repeatability | +/-0.2%of reading |
Base Rating | IP65 |
Make :- ENDRESS + HAUSER
Digital Flow Meter
Minimum Order Quantity: 1 Piece
Brand | ENDRESS + HAUSER |
Operating Temperature | -40 to +121 degree C |
Display Type | Digital |
Material | Stainless Steel |
Connection | FLANGE |
Application Media | Water, Any Liquid, Air |
Flow range | 5-50 GPM,18.9-190 LPM |
Supply Voltage | 12 to 24 VDC |
Make :- ENDRESS + HAUSER
Additional Information:
- Item Code: 36
- Production Capacity: 100
- Delivery Time: 4 WEEKS
- Packaging Details: STANDARD
Differential Pressure Transmitters
Minimum Order Quantity: 1 Number
Brand | ENDRESS + HAUSER |
Voltage | AC/DC |
Accuracy | ANY |
Operating Range | ANY |
Usage/Application | Industrial Process Monitoring |
Depth | ANY |
Height | ANY |
Additional Information:
- Delivery Time: 4 WEEKS
- Packaging Details: STD PACKAGE
Dc Temperature Transmiter
Minimum Order Quantity: 1 Number
Usage/Application | ANY |
Model Name/Number | ANY |
Voltage | DC |
Accuracy | ANY |
Operating Range | ANY |
Brand | ENDRESS + HAUSER |
Power supplies barriers supplies e.g. a transmitter with power, if required also in the Ex-area, and then transmits the galvanically isolated signal. With the optionally available HART® monitoring the status of the transmitter is monitored. Thus even just briefly occurring errors can be easily located.
Portfolio description
Our portfolio of DIN rail power supplies barriers provides:
· Power supplies for 2 or 4 wire transmitters
· Active barrier with power supply for safe separation of 4...20 mA current circuits in one device
· Power supplies barriers with bidirectional HART® transmission, communication sockets for HART® and integrated HART® resistor for sensor configuration
· Measuring principle / application example
Application example - power supply of a temperature transmitter:
If a 4 to 20 mA HART® head transmitter is installed in a thermometer it has to be supplied with power. An active barrier supplies the head transmitter with power, if required also in the Ex-area, and then transmits the galvanically isolated signal. With the optionally available HART®monitoring the status of the head transmitter is monitored. If an error arises a relay at the active barrier sends an alarm.
Application example for a passive barrier with SPS:
If a sensor in the Ex-area is to be supplied via a SPS the use of a passive barrier is necessary. The passive barrier transmits the supply from the Non-Ex area into the Ex-area and sends back the 4 to 20 mA signal. The passive barrier does not require a power supply as it receives its power from the 4 to 20 mA loop.
Benefits
· Wide range power supply, flexible power source
· Power supplies for 2 or 4 wire transmitters
· Galvanic isolation of 4 to 20 mA current circuits
· International Ex approvals, Germanischer Lloyd / marine approval available
· Sensor monitoring with early-warning system
Additional Information:
- Delivery Time: 4 WEEKS